SDR-240-24-MW
AC-DC slim Industrial DIN rail power supply, PFC Function, input voltage range 88-264VAC, output 240W 24VDC 10A
Features
- High efficiency 94% and low power dissipation
- 150% peak load capability
- Built-in active PFC function, PF>0.93
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling by free air convection
- Can be installed on DIN rail TS-35/7.5 or 15
- UL 508 (industrial control equipment) approved
- EN61000-6-2(EN50082-2) industrial immunity level
- Built-in DC OK relay contact
- 100% full load burn-in test
- 3 years warranty
Specifications
OUTPUT
DC VOLTAGE: 24V
RATED CURRENT: 10A
CURRENT RANGE: 0 ~ 10A
RATED POWER: 240W
PEAK CURRENT: 15A
PEAK POWER: 360W (3 sec.)
RIPPLE & NOISE (max.): 50mVp-p
VOLTAGE ADJUSTABLE RANGE: 24 ~ 28V
VOLTAGE TOLERANCE: ±1.0%
LINE REGULATION: ±0.5%
LOAD REGULATION: ±1.0%
SETUP, RISE TIME: 650ms, 60ms/230VAC 1300ms, 60ms/115VAC at full load
HOLD UP TIME (Typ.): 20ms/230VAC 20ms/115VAC at full load
INPUT
VOLTAGE RANGE: 88 ~ 264VAC
FREQUENCY RANGE: 47 ~ 63Hz
EFFICIENCY (Typ.): 94%
POWER FACTOR (Typ.): 0.94/230VAC 0.99/115VAC at full load
AC CURRENT (Typ.): 2.6A/115VAC 1.3A/230VAC
INRUSH CURRENT (Typ.): 33A/115VAC 55A/230VAC
LEAKAGE CURRENT: <1mA / 240VAC
PROTECTION
OVERLOAD: Normally works within 110 ~ 150% rated output power for more than 3 seconds and then shut down o/p voltage with auto-recovery
>150% rated power, constant current limiting with auto-recovery within 2 seconds and may cause to shut down if over 2 seconds
OVER VOLTAGE: 29 ~ 33V
Protection type: Shut down o/p voltage with auto-recovery
OVER TEMPERATURE: 95℃ ± 5℃ (TSW) detect on heatsink of power switch
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION
DC OK REALY CONTACT RATINGS (max.): 60Vdc/0.3A, 30Vdc/1A, 30Vac/0.5A resistive load
ENVIRONMENT
WORKING TEMP.: -25 ~ +70°C (Refer to "Derating Curve")
WORKING HUMIDITY: 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY: -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT: ±0.03%/°C (0 ~ 50°C)
VIBRATION: Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
SAFETY & EMC
SAFETY STANDARDS: UL508, TUV EN62368-1, EAC TP TC 004 approved; (meet EN60204-1)
WITHSTAND VOLTAGE: I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC
ISOLATION RESISTANCE: I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION: Compliance to EN55032 (CISPR32), EN61204-3 Class B, EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY: Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level, criteria A, EAC TP TC 020, SEMI F47 approved
MTBF: 169.3K hrs min. MIL-HDBK-217F (25℃)
DIMENSIONS: (WxHxD) 63 x 125.2 x 113.5 mm