ioThinx 4510
Advanced I/O, Ethernet network adapter, 3-in-1 serial port(s), -20 to 60°C operating temperature
Prodotti Correlati
Features and Benefits
› Easy tool-free installation and removal
› Easy web configuration and reconfiguration
› Built-in Modbus RTU gateway function
› Supports Modbus/SNMP/RESTful API
› Supports up to 32 I/O modules
› Wide operating temperature models available for -40 to 75°C
(-40 to 167°F) environments
Introduction
The ioThinx 4510 is an advanced modular remote I/O product with a
unique hardware and software design, making it an ideal solution for a
variety of industrial data acquisition applications.
The ioThinx 4510 has 2 Ethernet ports that support a daisy-chain
topology to save cabling cost, as well as 1 RS-232/422 port or 2
RS-485 (2-wire) ports to enable Modbus RTU to Modbus TCP/SNMP/
RESTful protocol conversion. In addition, the ioThinx 4510 supports
up to 32 I/O modules to help users collect data from field sites.
The ioThinx 4510 supports tool free installation and removal. With
its unique mechanical design, users can mount the module on the
DIN-rail and later remove it, all tool free. In addition, the ioThinx 4510
has new web user interface. Using the new friendly web design, users
can easily monitor the I/O status via the web dashboard and configure
I/O modules.
Easy Tool-Free Installation and Removal
The ioThinx 4500 Series has a unique mechanical design that reduces
the amount of time required for installation and removal. In fact,
screw drivers and other tools are not required for any part of the
hardware installation, including mounting the device on a DIN-rail, as
well as connecting the wiring for both communication and I/O signal
acquisition. Furthermore, no tools are required to remove the ioThinx
from a DIN-rail. Removing all of the modules from a DIN-Rail is also
easy using the latch and release tab.
Easy Web Configuration/Reconfiguration
For modular remote I/O setups, one of the greatest difficulties is
duplicating configuration settings to the current modules with different
module combinations. After adding, moving, or deleting one of the
modules, configuration of the unchanged modules, including the
Modbus address and RESTful APIs to the upper software, need to be
reconfigured. The ioThinx 4510’s user-friendly web configuration tool
was designed specifically to make configuration and reconfiguration
easy; no reconfiguration efforts required for the unchanged modules.
In addition, the ioThinx 4510’s web interface supports module/channel
unique names. This feature also applies to Modbus TCP and RESTful
API, saving users a lot of time on development and deployment.
Built-In Modbus RTU Gateway Function
The ioThinx 4510 supports Modbus RTU Master for retrieving field site
data from serial meters. After collecting the data, users can convert the
serial data to a variety of protocols, including Modbus TCP, SNMP, and
RESTful, allowing users to get field site data in their protocol of choice.
This two-in-one design reduces system complexity, the amount of
space required in the network topology, as well as overall installation
time. In addition, you can extend the useful life of legacy devices by
connecting them to Ethernet and access the devices using a preferred
protocol.
Input/Output Interface
Buttons: Reset button
Expansion Slots: Up to 32
Note: Compatible with 45MR Series only
Ethernet Interface
10/100BaseT(X) Ports (RJ45 connector): 2
Note: 1 MAC address
Protection: 1.5 kV magnetic isolation
Ethernet Software Features
Industrial Protocols: Modbus TCP Server (Slave), RESTful API,
SNMPv1/v2c/v3
Serial Interface
Serial Standards: 1 x RS-232/422 or 2 x RS-485 (2-wire)
Connector: Spring-type Euroblock terminal
Wiring: 16 to 28 AWG
Strip Length: 9 to 10 mm
Serial Communication Parameters
Parity: None, Even, Odd
Data Bits: 8
Stop Bits: 1, 2
Flow Control: RTS/CTS
Baudrate: 1200, 1800, 2400, 4800, 9600, 19200, 38400, 57600,
115200 bps
Serial Signals
RS-232: TxD, RxD, RTS, CTS, GND
RS-422: Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w: Data+, Data-, GND
Serial Software Features
Industrial Protocols: Modbus RTU Client (master)
System Power Parameters
Power Input: 12 to 48 VDC
Wiring: 12 to 26 AWG
Strip Length: 12 to 13 mm
Power Consumption (Max.): 800 mA @ 12 V
Output Current: Max. 1 A
Over-Voltage Protection: 55 VDC
Overload Protection: 1 A @ 25°C
Connection: Removable terminal block
Field Power Parameters
Power Input: 12/24 VDC
Wiring: 12 to 26 AWG
Strip Length: 12 to 13 mm
Output Current: Max. 2 A
Over-Voltage Protection: 33 VDC
Overload Protection: 2.5 A @ 25°C
Connection: Removable terminal block
Isolation
System Power to I/O Driver: 3k VDC or 2k Vrms
System Power to Field Power: 3k VDC or 2k Vrms
MTBF (mean time between failures)
Time: 1,451,040 hrs
Standards: Telcordia SR332
Physical Characteristics
Dimensions: 42.3 x 99 x 75 mm (1.67 x 3.9 x 2.95 in)
Weight: 173.5 g (0.382 lb)
Mounting: DIN-rail
Standards and Certifications
EMC: EN 55032, EN 55024, EN 61000-3-2/3-3
EMI: CISPR 32, FCC Part 15B Class A
EMS:
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 1 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8
Green Product: RoHS, CRoHS, WEEE
Environmental Limits
Operating Temperature:
Standard Models: -20 to 60°C (-4 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity: 5 to 95% (non-condensing)
Shock: IEC 60068-2-27
Vibration: IEC 60068-2-6
Altitude: Up to 4000 m
Warranty
Warranty Period: 5 years