OP-OLS4-10-0901PR
Optronics OLS4 ST/ST, LED Source 850/1300nm & Laser Source 1310/1550nm
Features
- Rugged, dependable tools
- Simple user interface minimizes training requirements
- Stabilized outputs for accurate loss measurements
- Wave ID supports testing two wavelengths simultaneously
- Field swappable output adapters provide flexibility
Introduction
SM/MM quad wavelength precision light source optimised for use with OPM5 Power Meter and M310 and M210 OTDRs. Designed for use in outside plant environments:
- Splash resistant controls
- Withstands one-meter drop test
- Controls designed for easy operation with gloves
- Field swappable output adapters allow access for cleaning optical port and supports multiple connector styles
- Efficient design provides long test time from globally available AA batteries. External power adapter available for extended testing or lab situations.
Optical Specifications
OLS4 (MM Optical Port):
Wavelength:
850 ±30 nm
1300 +30/-20 nm
Spectral Width:
45 nm (typ)
120 nm (typ)
Emitter Type: LED
Safety Class: Class I FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03
Output Power: >-20 dBm, 62.5 μm multimode
Output Stability: ±0.1 dB over 8 hours (after 5 minutes warm-up)
Tone Output: N/A
OLS4 (SM Optical Port):
Wavelength:
1310 ±20 nm
1550 ±20 nm
Spectral Width:
5 nm (max)
5 nm (max)
Emitter Type: Laser
Safety Class: Class I FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03
Output Power: 0 dBm, 9 μm single-mode
Output Stability:
±0.05 dB over 1 hour (after 15 minutes warm-up)
±0.1 dB over 8 hours (after 15 minutes warm-up)
Tone Output: 2 kHz
General Specifications
Available Adapters: SC FC, ST, LC
Power: 2 AA batteries, optional AC adaptor
Battery Life: SM port: 72 hours typical (40 hours minimum). MM port: 30 hours typical (20 hours minimum)
Operating Temperature: -10 °C to 50 °C, 90 % RH (non-condensing)
Storage Temperature: -30 °C to 60 °C, 90 % RH (non-condensing)
Size (H x W x D): 14.0 x 8.1 x 3.8 cm
Weight: 0.29 kg